Fire Rated Phenol Faced Plywood
Reaction to fire class Bfl-s1
For flooring applications
Smooth, mesh or hexa
Nationwide delivery of packs and commercial volumes to trade customers
For details and prices:
Birch / Alder Plywood Core
165g Phenolic Film (up to 480g available)
Mesh / Smooth (2.5 mesh per 1cm), Hexa / Smooth, Smooth Two Sides

Reaction to Fire
Item
Detail
Classification
Bfl-s1 to EN 13501-1+A1:2010 (floor covering)
Test methods
EN ISO 9239-1; EN ISO 11925-2
Critical heat flux (CHF/HF-30)
10.2 kW/m2 (threshold ≥ 8.0)
Smoke development (Sc)
9%·min (threshold ≤ 750)
Ignitability
No ignition; flame spread ≤ 150 mm
End-use condition
Non-combustible substrate per EN 13238:2011
(fibre cement board 8 ± 2mm, 1800 ±200 kg/m3, A2fl-s1), without attachment (e.g. adhesive)
Fire classification Bfl-s1 achieved when installed as tested and declared by the manufacturer. Designers and specifiers remain responsible for determining suitability for the intended end use and construction build-up.
CE marked under AVCP System 2+. Full Declaration of Performance available on request.
| Item | Detail |
|---|---|
| Classification | Bfl-s1 to EN 13501-1+A1:2010 (floor covering) |
| Test methods | EN ISO 9239-1; EN ISO 11925-2 |
| Critical heat flux (CHF/HF-30) | 10.2 KW/M2 (threshold ≥ 8.0) |
| Smoke development (Sc) | 9% min (threshold ≤ 750) |
| Ignitability | No ignition; flame spread ≤ 150 mm |
| End-use condition | Non-combustible substrate per EN 13238:2011 (fibre cement board 8 ± 2mm, 1800 ±200 kg/m3, A2fl-s1), without attachment (e.g. adhesive) |
Applications
Stage Floors
Mesh or Hexa anti-slip finish
Modular & Temporary Flooring
Exhibition Flooring
Event Infrastructure
Walkways, Staging, Platforms
FLOORING USE ONLY - please read before specifying
This classification applies to flooring only, when the panel is installed as tested. Bfl-s1 should not be assumed to apply to wall linings, ceilings, cladding or other end uses. Alternative end uses may require separate assessment and testing.
The classification applies to panels 12mm thick and above, tested on a non-combustible fibre cement board substrate, laid without adhesive fixing. Designers and specifiers remain responsible for confirming suitability for their intended build-up.
Thickness & Packing
| Thickness | No. of Plies | Small Packing | Large Packing |
|---|---|---|---|
| 12mm | 9 ply | 33 sheets | 50 sheets |
| 15mm | 11 ply | 26 sheets | 40 sheets |
| 18mm | 13 ply | 22 sheets | 35 sheets |
| 21mm | 15 ply | 19 sheets | 30 sheets |
| 24mm | 17 ply | 17 sheets | 25 sheets |
| 27mm | 19 ply | 14 sheets | 22 sheets |
| 30mm | 21 ply | 13 sheets | 20 sheets |
| 35mm | 25 ply | 12 sheets | 17 sheets |
| 40mm | 29 ply | 10 sheets | 15 sheets |
Range shown reflects the tested and classified thicknesses for this product (12mm-40mm)
Plies
The number of laminations
1.4mm thick, laid-up with grain alternating at 90 degrees
Packing
Quantities shown are standard mill packing
For special order items, pack quantities can be altered
Panel Sizes
| Metric | Imperial |
|---|---|
| 2440 x 1220 | 8ft x 4ft |
| 1250 x 2500 |
1525 x 3050 (5ft x 10ft) is not produced by the mill for this product
Specifications
Fire rated phenol faced plywood, Bfl-s1 (flooring)
Phenol Overlay
Paper impregnated with phenol resin
Moisture and chemical resistant
165g/m2 standard film weight (both sides)
Available up to 480g/m2 for increased wear resistance
Reaction to Fire
Bfl-s1 to EN 13501-1+A1:2010
Flooring use only, 12mm and above
Content of PCP
Does not contain pentachlorophenol
Edge Sealing
Sealed with waterproof acrylic paint
Must be re-sealed if cut on site
Slip Rating
Conforms to anti-slip rating R13
According to DIN 51130
Weight
650-800 kg/m³ (EN 323)
e.g. 18mm 8x4 weighs approx. 37kg
Wear Resistance
Rolling Test (EN 1818) up to 9,000 cycles, 300kg load
Bonding Quality
EN314-2 class 3 exterior conditions
Use class: exterior, EN 636-3
Dark brown glue-line, phenol resin
Moisture Content
10% (+/- 5%) to EN322
Formaldehyde
In accordance with the standard EN 13986
the formaldehyde emission meets the Class E1 requirements
(test method EN 717 Part 2)
Cutting Service
Cut to size & CNC machined panels
We offer a full cutting and processing service
Router, drill, chamfer or machining
Edges are sealed with external paint
Cutting on site
If panels are cut or machined on site, exposed edges must be re-sealed with a suitable waterproof edge sealant. Unsealed edges are not covered by the tested and declared performance of this product.
For more information on our cutting & machining services
Colours
Dark brown or black
Phenol mesh or smooth faced plywood is not manufactured or offered as a decorative panel. We only recommend specifying for industrial / light industrial and utility applications.
As this is intended for industrial applications, minor visual defects (rippling, blemishes, overlaps, scratches) are permitted in the grading rules.
Phenol film is not UV fast and the colour will change over time.
Other Fire Rated Panels
Looking for fire rated plywood for wall lining, ceilings or general construction?
See our standard
Contra-Burn Fire Retardant Plywood, rated to Euroclass B and C
Other Coated Panels
Our range of overlaid birch plywood panels